Overview

 

CODE REASON EFFECT
Fault Code: 1669
PID: 
SPN: 1761
FMI: 3/3
LAMP: Amber
SRT: 

 

High signal voltage detected at the catalyst tank level sensor circuit.

 

 

Possible reduced engine performance.

Circuit Description

The aftertreatment diesel exhaust fluid tank level sensor is used to monitor the aftertreatment diesel exhaust fluid level inside the aftertreatment diesel exhaust fluid tank.

Component Location

The aftertreatment diesel exhaust fluid tank level sensor is located in the aftertreatment diesel exhaust fluid tank. Location of the tank and level sensor is OEM dependent. Refer to the OEM service manual.

 

Conditions for Running the Diagnostics

This diagnostic runs continuously when the keyswitch is in the ON position or when the engine is running.

Conditions for Setting the Fault Codes

The Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid tank level sensor signal voltage was out of range high.

Action Taken When the Fault Code is Active

The ECM illuminates the amber CHECK ENGINE lamp immediately when the diagnostic runs and fails.

Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.

Conditions for Clearing the Fault Code

  • To validate the repair, perform a key cycle, start the engine and let it idle for 1 minute.
  • The fault code status displayed by the recommended Cummins® electronic service tool or equivalent will change to INACTIVE immediately after the diagnostic runs and passes.
  • The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
  • The “Reset All Faults” command in the recommended Cummins® electronic service tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

 

Shop Talk

Possible causes of this fault code include:

Signal circuit open or shorted to ground in the engine harness or sensor

  • Supply wire open or shorted to ground.

A malfunctioning aftertreatment diesel exhaust fluid tank level sensor

The type of diesel exhaust fluid tank temperature and level sensor used can vary depending on the vehicle OEM. As a result, the physical and/or electrical sensor configuration may vary slightly from what is shown in the troubleshooting and wiring diagram information.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Solution: S00000047

Verification

Conditions

  • Turn keyswitch ON.
  • Connect the recommended Cummins® electronic service tool or equivalent.

Action

  • Use the recommended Cummins® electronic service tool or equivalent to read the fault codes.

Specification

Before troubleshooting this fault code, troubleshoot any fault code that is active or has more than one inactive count within the last 25 engine operating hours from the following list:

  • Sensor supply 5: 1695, 1696

Linked Solutions

  • None

Repair

  • Perform a search on the appropriate fault codes.

Validation

  • None

Solution: S00003205

Verification

Conditions

  • Turn keyswitch OFF.
  • Disconnect the aftertreatment diesel exhaust fluid tank level sensor from the OEM wiring harness.

Action

  • Inspect the pins and connectors for damage.

Refer to Procedure 019-361

  • Turn keyswitch ON.
  • Measure the voltage between the aftertreatment diesel exhaust fluid tank level sensor voltage SUPPLY pin and the aftertreatment diesel exhaust fluid tank level sensor voltage RETURN pin at the OEM wiring harness connector.
  • Refer to the circuit diagram or wiring diagram for connector pin identification.

Specification

  • If the voltage is between 4.75 to 5.25 VDC on 5 volt supply systems or within 1 VDC of battery voltage on 12 volt supply systems, then proceed to the next solution.
  • If the voltage is not between 4.75 to 5.25 VDC on 5 volt supply systems or within 1 VDC of battery voltage on 12 volt supply systems, then proceed to the Linked Solutions section.

Linked Solutions

  • Fuse check

Refer to S00001852

  • Aftertreatment diesel exhaust fluid tank level sensor voltage check.

Refer to S00003206

Repair

  • No additional action is required for this solution.

Validation

  • None

Solution: S00001852

Verification

Conditions

  • Turn keyswitch OFF.

Action

  • Inspect the fuse.

Refer to Procedure 019-198

Specification

  • If the fuse is found to be blown or damaged, then proceed to Repair section.

Linked Solutions

  • None

Repair

  • Replace the fuse.

Refer to Procedure 019-198

Validation

  • Connect all components
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Disable the fault code.
  • Operate the engine within the «Conditions for Clearing the Fault Code» found in the Overview section of the troubleshooting procedure.
  • Verify that the fault code is no longer active.
  • Check ECM Calibration Revision History
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
  • Refer to ECM Calibration Revision History Database.

Solution: S00003206

Verification

Conditions

  • Turn keyswitch OFF.
  • Disconnect the 86-pin aftertreatment diesel exhaust fluid controller OEM wiring harness connector.

Action

  • Inspect the pins and connectors for damage.

Refer to Procedure 019-361

  • Turn keyswitch ON.
  • Measure the resistance between the aftertreatment diesel exhaust fluid tank level sensor SUPPLY pin at the sensor connector and the aftertreatment diesel exhaust fluid tank level sensor SUPPLY pin at the aftertreatment diesel exhaust fluid controller harness 86-pin connector.
  • Measure the resistance between the aftertreatment diesel exhaust fluid tank level sensor RETURN pin at the sensor connector and the aftertreatment diesel exhaust fluid tank level sensor RETURN pin at the aftertreatment diesel exhaust fluid controller harness 86-pin connector.
  • Refer to the circuit diagram or wiring diagram for connector pin identification.

Specification

  • A malfunctioning OEM wiring harness has been detected if the resistance is greater than the following specification: 10 Ω
  • A malfunctioning aftertreatment diesel exhaust fluid controller has been detected if the resistance is less than the following specification: 10 Ω

Linked Solutions

  • None

Repair

Repair or replace only the components that were found to be out of specification.

  • Replace aftertreatment diesel exhaust fluid controller.

Refer to Procedure 011-057

  • Repair or replace the OEM wiring harness.

Refer to Procedure 019-071

  • Replace the fuse.

Refer to Procedure 019-198

Validation

  • Connect all components
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Disable the fault code.
  • Operate the engine within the «Conditions for Clearing the Fault Code» found in the Overview section of the troubleshooting procedure.
  • Verify that the fault code is no longer active.
  • Check ECM Calibration Revision History
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
  • Refer to ECM Calibration Revision History Database.

Solution: S00000392

Verification

Conditions

  • Turn keyswitch OFF.
  • Disconnect the aftertreatment diesel exhaust fluid tank level sensor from the OEM wiring harness.

Action

  • Inspect the pins and connectors for damage.

Refer to Procedure 019-361

  • Place a jumper wire between the aftertreatment diesel exhaust fluid tank level sensor SIGNAL pin and the aftertreatment diesel exhaust fluid tank level sensor RETURN pin at the aftertreatment diesel exhaust fluid tank level sensor connector of the OEM wiring harness.
  • Refer to the circuit diagram or wiring diagram for connector pin identification.
  • Turn keyswitch ON.
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Wait 30 seconds before checking the circuit response.
  • Use the recommended Cummins® electronic service tool or equivalent to read the fault codes.

Specification

  • A malfunctioning aftertreatment diesel exhaust fluid tank level sensor has been detected if the following fault code became active with the jumper wire in place: 1668

Linked Solutions

  • None

Repair

  • Replace the aftertreatment diesel exhaust fluid tank level sensor.

Refer to OEM Service Manual

Validation

  • Connect all components
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Disable the fault code.
  • Operate the engine within the «Conditions for Clearing the Fault Code» found in the Overview section of the troubleshooting procedure.
  • Verify that the fault code is no longer active.
  • Check ECM Calibration Revision History
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
  • Refer to ECM Calibration Revision History Database.

Solution: S00000443

Verification

Conditions

  • Connect all components.
  • Turn keyswitch ON.
  • Connect the recommended Cummins® electronic service tool or equivalent.

Action

  • Use the recommended Cummins® electronic service tool or equivalent to read the fault codes.
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revision listed in the ECM calibration revision history for applicable changes.

Specification

  • If a calibration update for this fault code is available, the ECM calibration revision must be that revision or higher.

Linked Solutions

  • None

Repair

  • Prior to downloading the ECM calibration, check to see that all job images and all other troubleshooting has been documented as downloading an ECM calibration will remove the fault codes on the ECM.
  • Download the updated ECM calibration code.

Refer to Procedure 019-032

Validation

  • Connect all components
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Disable the fault code.
  • Operate the engine within the «Conditions for Clearing the Fault Code» found in the Overview section of the troubleshooting procedure.
  • Verify that the fault code is no longer active.
  • Check ECM Calibration Revision History
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
  • Refer to ECM Calibration Revision History Database.

If all steps have been completed and no root cause has been identified, then follow the technical escalation process.