Overview

 

CODE REASON EFFECT
Fault Code: 3574
PID: 
SPN: 4334
FMI: 1/18
LAMP: Amber
SRT: 

 

Low diesel exhaust fluid pressure has been detected in the dosing unit.

 

 

Possible reduced engine performance.

Circuit Description

The Engine Control Module (ECM) provides a 5 volt supply and a ground to the aftertreatment diesel exhaust fluid pressure sensor. The pressure sensor provides a signal to the ECM on the sensor signal circuit. This sensor signal voltage changes, based on the aftertreatment diesel exhaust fluid pressure supplied by the dosing unit. The ECM will detect a low signal voltage at low diesel exhaust fluid pressures, and a high signal voltage at high diesel exhaust fluid pressures.

Component Location

The aftertreatment diesel exhaust fluid pressure sensor is internal to the aftertreatment diesel exhaust fluid dosing unit and can not be serviced separately.

 

Conditions for Running the Diagnostics

This diagnostic runs when the diesel exhaust fluid dosing unit is in the priming or dosing state.

Conditions for Setting the Fault Codes

The Engine Control Module (ECM) detected the aftertreatment diesel exhaust fluid pressure was less than a threshold.

Action Taken When the Fault Code is Active

  • The ECM illuminates the amber CHECK ENGINE lamp and/or the malfunction indicator lamp (MIL) immediately when the diagnostic runs and fails.

Engine torque will be reduced if the engine is operated for an extended period of time with this fault active.

Engine torque will be severely reduced.

Vehicle speed will be limited to 8 km [5 mi] per hour after extended engine operation with the fault code active.

Conditions for Clearing the Fault Code

  • To validate the repair, perform the «Aftertreatment Diesel Exhaust Fluid Doser Pump Override Test» found under «ECM Diagnostic Tests» in the recommended Cummins® electronic service tool or equivalent.
  • The fault code status displayed by the recommended Cummins® electronic service tool or equivalent will change to INACTIVE immediately after the diagnostic runs and passes.
  • The ECM will turn off the amber CHECK ENGINE lamp immediately after the diagnostic runs and passes.
  • For On-Board Diagnostics (OBD) engines, the ECM will extinguish the Malfunction Indicator Lamp (MIL) after three consecutive trips where the diagnostic runs and passes.
  • The “Reset All Faults” command in the recommended Cummins® electronic service tool or equivalent can be used to clear active and inactive faults, as well as extinguish the MIL for OBD applications.

 

Shop Talk

Troubleshoot other active SCR related faults before this fault.

Possible causes of this fault code include:

Low diesel exhaust fluid tank level

Blocked, restricted, or frozen diesel exhaust fluid dosing unit supply line

Blocked or restricted diesel exhaust fluid tank filter

Blocked or restricted diesel exhaust fluid dosing unit filter

Blocked or restricted diesel exhaust fluid dosing unit supply line fitting

Malfunctioning diesel exhaust fluid dosing unit

Contaminated diesel exhaust fluid

Debris from the diesel exhaust fluid tank. If debris is found in the diesel exhaust fluid tank, clean the diesel exhaust fluid tank thoroughly and fill with certified diesel exhaust fluid.

Reference the appropriate OEM wiring diagram when troubleshooting circuits that utilize wiring supplied by the OEM.

For intermittent power supply and datalink communication issues with Aftertreatment Components, it is highly recommended that the OEM Power Distribution Center fuses and relays be thoroughly checked for loose, missing or intermittent connections.

Solution: S00001991

Verification

Conditions

  • Turn keyswitch ON.
  • Connect the recommended Cummins® electronic service tool or equivalent.

Action

  • Use the recommended Cummins® electronic service tool or equivalent to read the fault codes.

Specification

Before troubleshooting this fault code, troubleshoot any fault code that is active or has more than one inactive count within the last 25 engine operating hours from the following list:

  • Aftertreatment diesel exhaust fluid system: 1671, 1673, 1681, 3497, 3498, 3565, 3566, 3567, 3568, 3571, 3572, 3577, 3578, 3579, 3612, 3679, 1713

Linked Solutions

  • None

Repair

  • Perform a search on the appropriate fault codes.

Validation

  • None

Solution: S00002928

Verification

Conditions

  • Turn keyswitch OFF.
  • Disconnect the aftertreatment diesel exhaust fluid dosing unit from the OEM wiring harness.

Action

  • Inspect the pins and connectors for damage.

Refer to Procedure 019-361

  • Inspect all connections for corrosion or loose connections.

Refer to Procedure 019-361

Specification

  • If the aftertreatment diesel exhaust fluid dosing unit connector or the aftertreatment diesel exhaust fluid dosing unit wiring harness connector show signs of diesel exhaust fluid, then a malfunctioning aftertreatment diesel exhaust fluid dosing unit connector has been detected.

Linked Solutions

  • None

Repair

Repair or replace only the components that were found to be out of specification.

  • Replace aftertreatment diesel exhaust fluid dosing unit.

Refer to Procedure 011-058

Refer to Service Bulletin 4310705

Validation

  • Connect all components
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Disable the fault code.
  • Operate the engine within the «Conditions for Clearing the Fault Code» found in the Overview section of the troubleshooting procedure.
  • Verify that the fault code is no longer active.
  • Check ECM Calibration Revision History
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
  • Refer to ECM Calibration Revision History Database.

Solution: S00000664

Verification

Conditions

  • Turn keyswitch OFF.

Action

  • Verify the lines are not swapped at the dosing unit, dosing valve or diesel exhaust fluid tank connections.

Refer to Procedure 011-058

  • Visually inspect the aftertreatment diesel exhaust fluid tank connections for cracks or pitting.
  • Visually inspect the aftertreatment diesel exhaust fluid tank vent line for restrictions.
  • Visually inspect the aftertreatment diesel exhaust fluid line for damage.
  • Visually inspect both dosing unit connections and fittings for loose, leaking, or damaged connections.
  • Disconnect the suction line and pressure line dosing unit connectors and look for signs of build-up or blockage.

Refer to Procedure 011-058

  • Inspect the aftertreatment diesel exhaust fluid dosing unit inlet connector screen.

Refer to Procedure 011-058

  • Visually inspect the suction line for signs of leakage or openings which will allow the dosing unit to suck in air with the diesel exhaust fluid.
  • Visually inspect the pressure line for signs of leakage or rupture.
  • Verify proper sealing at all connection points, including diesel exhaust fluid tank, dosing unit, and dosing valve.

Refer to Procedure 011-058

Specification

  • If there are aftertreament diesel exhaust fluid lines reversed, damaged, leaking or restricted connections found, then proceed to the Repair section.

Linked Solutions

  • None

Repair

  • Repair or replace damaged components.

Refer to OEM Service Manual

  • Replace the aftertreatment diesel exhaust fluid dosing unit inlet connector screen.

Refer to Procedure 011-058

Validation

  • Connect all components
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Disable the fault code.
  • Operate the engine within the «Conditions for Clearing the Fault Code» found in the Overview section of the troubleshooting procedure.
  • Verify that the fault code is no longer active.
  • Check ECM Calibration Revision History
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
  • Refer to ECM Calibration Revision History Database.

Solution: S00000563

Verification

Conditions

  • Turn keyswitch OFF.

Action

  • Inspect the aftertreatment diesel exhaust fluid in the tank for signs of debris or contamination.

Refer to Procedure 011-056

  • Use a diesel exhaust fluid refractometer to measure the concentration of the diesel exhaust fluid in the tank.

Refer to Service Bulletin 4021566

Specification

  • If there are signs of contaminates in the aftertreatment diesel exhaust fluid, then proceed to the Repair section.

Linked Solutions

  • None

Repair

  • Drain the diesel exhaust fluid tank, clean thoroughly and refill with pure diesel exhaust fluid.

Refer to Procedure 011-056

Validation

  • Connect all components
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Disable the fault code.
  • Operate the engine within the «Conditions for Clearing the Fault Code» found in the Overview section of the troubleshooting procedure.
  • Verify that the fault code is no longer active.
  • Check ECM Calibration Revision History
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
  • Refer to ECM Calibration Revision History Database.

Solution: S00000360

Verification

Conditions

  • Turn keyswitch ON.
  • Connect the recommended Cummins® electronic service tool or equivalent.

Action

  • Perform the Aftertreatment Diesel Exhaust Fluid Dosing Unit Suction Test.

Refer to Procedure 011-121

Specification

  • If the vacuum in diagnostic line does not meet specification, then proceed to the Linked Solutions section.

Linked Solutions

Click on the link below:

  • Aftertreatment diesel exhaust fluid dosing unit is malfunctioning

Refer to S00000522

Repair

  • No additional action is required for this solution.

Validation

  • Connect all components
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Disable the fault code.
  • Operate the engine within the «Conditions for Clearing the Fault Code» found in the Overview section of the troubleshooting procedure.
  • Verify that the fault code is no longer active.
  • Check ECM Calibration Revision History
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
  • Refer to ECM Calibration Revision History Database.

Solution: S00000522

Verification

Conditions

  • Turn keyswitch OFF.

Action

  • Perform the Aftertreatment Diesel Exhaust Fluid Dosing Unit Non Air Flush.

Refer to Procedure 011-058

  • Perform the Aftertreatment Diesel Exhaust Fluid Dosing Unit Suction Test.

Refer to Procedure 011-121

Specification

  • If the Aftertreatment Diesel Exhaust Fluid Dosing Unit Non Air Flush does not meet specifciation, then proceed to the Repair section.
  • If the Aftertreatment Diesel Exhaust Fluid Dosing Unit Suction Test does not meet specification, then proceed to the Repair section.

Linked Solutions

  • None

Repair

Repair or replace only the components that were found to be out of specification.

  • Cleaning of the aftertreatment diesel exhaust fluid dosing system resolved the issue.
  • Replace aftertreatment diesel exhaust fluid dosing unit.

Refer to Procedure 011-058

Validation

  • Connect all components
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Disable the fault code.
  • Operate the engine within the «Conditions for Clearing the Fault Code» found in the Overview section of the troubleshooting procedure.
  • Verify that the fault code is no longer active.
  • Check ECM Calibration Revision History
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
  • Refer to ECM Calibration Revision History Database.

Solution: S00000732

Verification

Conditions

  • Turn keyswitch ON.
  • Connect the recommended Cummins® electronic service tool or equivalent.

Action

  • Check the aftertreatment diesel exhaust fluid dosing unit intake restriction.

Refer to Procedure 011-086

Specification

  • If the vacuum in diagnostic line is not within specification, then proceed to the Repair section.

Linked Solutions

  • None

Repair

Repair or replace only the components that were found to be out of specification.

  • Replace the diesel exhaust fluid tank filter.

Refer to OEM Service Manual

  • Clean or replace the aftertreatment diesel exhaust fluid intake line.

Refer to OEM Service Manual

  • Clean or replace the aftertreatment diesel exhaust fluid tank header.

Refer to OEM Service Manual

  • Clean or replace the aftertreatment diesel exhaust fluid tank vent.

Refer to OEM Service Manual

Validation

  • Connect all components
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Disable the fault code.
  • Operate the engine within the «Conditions for Clearing the Fault Code» found in the Overview section of the troubleshooting procedure.
  • Verify that the fault code is no longer active.
  • Check ECM Calibration Revision History
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
  • Refer to ECM Calibration Revision History Database.

Solution: S00000730

Verification

Conditions

  • Turn keyswitch ON.

Action

  • Check for air in the diesel exhaust fluid.

Refer to Procedure 011-075

Specification

  • If a line, fitting, connection, or dosing unit is leaking, then a malfunction has been detected in the aftertreatment diesel exhaust fluid system or dosing unit.

Linked Solutions

  • None

Repair

  • Repair or replace the leaking components.

Refer to Procedure 011-075

Validation

  • Connect all components
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Disable the fault code.
  • Operate the engine within the «Conditions for Clearing the Fault Code» found in the Overview section of the troubleshooting procedure.
  • Verify that the fault code is no longer active.
  • Check ECM Calibration Revision History
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
  • Refer to ECM Calibration Revision History Database.

Solution: S00002761

Verification

Conditions

  • Reconnect all aftertreatment diesel exhaust fluid lines and electrical connectors to the dosing unit and aftertreatment diesel exhaust fluid tank if they have been previously disconnected during troubleshooting.

Action

  • Remove the aftertreatment diesel exhaust fluid dosing valve from the decomposition tube.

Refer to Procedure 011-059

  • Turn keyswitch ON.
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Use the recommended Cummins® electronic service tool or equivalent.
  • Perform the Aftertreatment Diesel Exhaust Fluid Doser Pump Override Test.

Refer to Procedure 011-063

The Aftertreatment Diesel Exhaust Fluid Doser Pump Override test can only be ran twice before a key cycle needs to be performed.

Specification

  • If the Aftertreatment Diesel Exhaust Fluid Doser Pump Override Test meets the specification, then proceed to the next solution.
  • If the Aftertreatment Diesel Exhaust Fluid Doser Pump Override Test does not meet the specification, then proceed to the Linked Solutions section.

Linked Solutions

Click on the link below:

  • Aftertreatment diesel exhaust fluid dosing valve is malfunctioning

Refer to S00002764

Repair

  • No additional action is required for this solution.

Validation

  • Connect all components
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Disable the fault code.
  • Operate the engine within the «Conditions for Clearing the Fault Code» found in the Overview section of the troubleshooting procedure.
  • Verify that the fault code is no longer active.
  • Check ECM Calibration Revision History
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
  • Refer to ECM Calibration Revision History Database.

Solution: S00002764

Verification

Conditions

  • Turn keyswitch OFF.
  • Connect the recommended Cummins® electronic service tool or equivalent.

Action

  • Clean the aftertreatment diesel exhaust fluid dosing valve.
  • Turn keyswitch ON.
  • Use the recommended Cummins® electronic service tool or equivalent.
  • Perform the Aftertreatment Diesel Exhaust Fluid Doser Pump Override Test.

Refer to Procedure 011-063

Specification

  • If the Aftertreatment Diesel Exhaust Fluid Doser Pump Override Test is not within specification, then proceed to the Repair section.

Linked Solutions

  • None

Repair

Repair or replace only the components that were found to be out of specification.

  • Replace the aftertreatment diesel exhaust fluid dosing valve.

Refer to Procedure 011-059

  • Replace aftertreatment diesel exhaust fluid dosing unit.

Refer to Procedure 011-058

Validation

  • Connect all components
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Disable the fault code.
  • Operate the engine within the «Conditions for Clearing the Fault Code» found in the Overview section of the troubleshooting procedure.
  • Verify that the fault code is no longer active.
  • Check ECM Calibration Revision History
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
  • Refer to ECM Calibration Revision History Database.

Solution: S00000443

Verification

Conditions

  • Connect all components.
  • Turn keyswitch ON.
  • Connect the recommended Cummins® electronic service tool or equivalent.

Action

  • Use the recommended Cummins® electronic service tool or equivalent to read the fault codes.
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revision listed in the ECM calibration revision history for applicable changes.

Specification

  • If a calibration update for this fault code is available, the ECM calibration revision must be that revision or higher.

Linked Solutions

  • None

Repair

  • Prior to downloading the ECM calibration, check to see that all job images and all other troubleshooting has been documented as downloading an ECM calibration will remove the fault codes on the ECM.
  • Download the updated ECM calibration code.

Refer to Procedure 019-032

Validation

  • Connect all components
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Disable the fault code.
  • Operate the engine within the «Conditions for Clearing the Fault Code» found in the Overview section of the troubleshooting procedure.
  • Verify that the fault code is no longer active.
  • Check ECM Calibration Revision History
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
  • Refer to ECM Calibration Revision History Database.

Solution: S00001431

Verification

Conditions

  • None

Action

  • Verify all preceding solution verifications for this fault code have been performed.

Specification

  • If the fault code is still active or inactive with more than one count within the last 25 engine hours and all the preceding solution verifications have been performed, then a malfunctioning aftertreatment diesel exhaust fluid dosing unit has been detected.

Linked Solutions

  • None

Repair

  • Replace aftertreatment diesel exhaust fluid dosing unit.

Refer to Procedure 011-058

Validation

  • Connect all components
  • Connect the recommended Cummins® electronic service tool or equivalent.
  • Disable the fault code.
  • Operate the engine within the «Conditions for Clearing the Fault Code» found in the Overview section of the troubleshooting procedure.
  • Verify that the fault code is no longer active.
  • Check ECM Calibration Revision History
  • Use the recommended Cummins® electronic service tool or equivalent to find the current ECM code and revision number in the ECM.
  • Compare the ECM code and revision number in the ECM to the calibration revisions listed in the ECM Calibration Revision History Database for applicable changes related to this fault code.
  • Refer to ECM Calibration Revision History Database.

If all steps have been completed and no root cause has been identified, then follow the technical escalation process.